Einschraubventile
Ventilgehäuse
Standard-Ventilkombinationen
Kundenspezifische Ventilkombinationen
Verstärker und Zubehör
Zubehör
Einschraubventilbohrungen / Formwerkzeuge
Preise
FAQs
Technische Informationen
Literatur
Produktauswahlprogramm
Produktsuche
Verrohrungsgehäuse
Zwischenplatten
Auf Hydraulikmotoren flanschbare Gehäuse
Anschlussplatten
Gehäuseauswahlprogramm
Download STEP-Dateien
FAQs zu Einschraubventilen
FAQs zu Ventilgehäusen
FAQs zu Standard-Ventilkombinationen
Katalogbestellung
Literatur-Download
Über uns
SUN Highlights
Stellenangebote
Investor Informationen
Katalogbestellung
Veranstaltungskalender
Kontakt
Loading...Please Wait
Product Selector Tool
Locates cartridges, manifolds, and assemblies. Results include only those products represented on the web.
STEP 1: Select the functional requirement.
Function
Select Function
accumulator sense, pump unload
air bleed and start-up
cavity plug
check
converter
counterbalance
directional
diverter
flow control
flow divider
flow divider-combiner
flow fuse
load control
logic element
modulating element
needle
pilot-to-open check
pressure reducing
pressure reducing/relieving
relief
sequence
shuttle
solenoid-operated directional
throttle
vented counterbalance
vented pilot-to-open check
Cavity
Select Cavity
T-2A
T-3A
T-5A
T-8A
T-9A
T-10A
T-11A
T-13A
T-16A
T-17A
T-18A
T-19A
T-21A
T-22A
T-23A
T-24A
T-31A
T-32A
T-33A
T-34A
T-52A
T-53A
T-61A
T-62A
T-63A
T-64A
T-162A
T-163A
Or enter a 4-letter cartridge or 3-letter manifold model code.
Click on tabs below for results.
Please wait, the application is gathering data.
Please wait, the application is gathering results.
STEP 2: Select the product type descriptors.
Cartridge Descriptors
Select Capacity
.035 in. (0,9 mm)
.05 in. (1,27 mm)
.06 in. (1,50 mm)
.09 in. (2,3 mm)
.11 in. (2,8 mm)
.13 in. (3,3 mm)
.16 in. (4 mm)
.19 in. (4,8 mm)
.25 in. (6,4 mm)
.28 in. (7,1 mm)
.33 in. (8,4 mm)
.38 in. (9,7 mm)
.5 in. (12,7 mm)
.56 in. (14,2 mm)
.69 in. (17,5 mm)
.85 in. (21,6 mm)
46 in³/min. (0,75 L/min.)
.1 - 12 gpm (0,4 - 45 L/min.)
.25 gpm (1 L/min.)
.3 - 1.5 gpm (1 - 6 L/min.)
.5 gpm (2 L/min.)
.6 - 3 gpm (2,5 - 12 L/min.)
1.25 gpm (4,7 L/min.)
1.5 - 8 gpm (6 - 30 L/min.)
2 - 10 gpm (8 - 40 L/min.)
2.25 gpm (8,5 L/min.)
2.5 gpm (10 L/min.)
3 - 15 gpm (12 - 60 L/min.)
3 gpm (11 L/min.)
4 - 20 gpm (15 - 80 L/min.)
4 - 50 gpm (15 - 200 L/min.)
4 gpm (15 L/min.)
5 gpm (20 L/min.)
6 - 30 gpm (23 - 120 L/min.)
6 gpm (23 L/min.)
7 - 10 gpm (28 - 40 L/min.)
7 gpm (28 L/min.)
7.5 gpm (30 L/min.)
8 - 40 gpm (32 - 160 L/min.)
8 gpm (30 L/min.)
1 gpm (4 L/min.)
10 - 13 gpm (40 - 50 L/min.)
10 gpm (40 L/min.)
11 - 30 gpm (38 - 120 L/min.)
12 - 60 gpm (45 - 240 L/min.)
12 gpm (45 L/min.)
15 - 80 gpm (60 - 320 L/min.)
15 gpm (60 L/min.)
18 gpm (70 L/min.)
19.8 gpm (75 L/min.)
20 - 30 gpm (80 - 120 L/min.)
20 gpm (80 L/min.)
20.8 gpm (79 L/min.)
25 - 100 gpm (95 - 380 L/min.)
25 gpm (95 L/min.)
30 gpm (120 L/min.)
40 - 60 gpm (160 - 240 L/min.)
40 gpm (160 L/min.)
50 - 200 gpm (200 - 760 L/min.)
50 gpm (200 L/min.)
60 gpm (240 L/min.)
80 - 120 gpm (320 - 480 L/min.)
80 gpm (320 L/min.)
9 gpm (34 L/min.)
100 gpm (380 L/min.)
120 gpm (480 L/min.)
160 gpm (640 L/min.)
200 gpm (760 L/min.)
240 gpm (900 L/min.)
2-way
3-way
4-way
6-way
air-controlled
air-operated
all ports blocked
all ports open
atmospherically referenced
back-to-back
back-to-back check/
balanced
balanced piston
balanced poppet
bi-directional
bypass orifice
bypass/restrictive, priority
center bleed
closed center
delayed shift
direct-acting
drilled piston orifice
dual
dual pressure
electro-proportional
fast-acting
filter screen
fixed setting
free flow nose to side
free flow side to nose
fully adjustable
high pressure setting with no command
hydraulically-controlled
hydraulically-operated
integral T-8A control cavity
kick-down
load reactive
main stage
manually-operated
mechanically-operated
meter in
non-adjustable
non-pressure compensated
pilot operated
pilot shifted
pilot-to-close
pilot-to-open
pilot-to-shift
port 1 to 2 open, port 3 blocked
port 1 to 3 open, port 2 blocked
port 1 to 3 open, ports 2 and 4 blocked
port 1 to external port, port 2 blocked
port 1 to external port, ports 2 and 3 blocked
port 2 to 3 open, port 1 blocked
port 2 to 3 open, ports 1 and 4 blocked
port 2 to external port, port 1 blocked
port 3 to 4 open, ports 1 and 2 blocked
ports 3 and 4 or port 5 and 6 blocked, all other ports open
position switch
pressure adjustable
pressure compensated
proportional
relief function
restrictive
reverse flow check
semi-restrictive
single ball
soft
soft shift
spring biased closed
spring biased open
spring offset
standard capacity
synchronizing
T-10A cavity
T-11A cavity
T-13A cavity
T-162A cavity
T-16A cavity
T-17A cavity
T-18A cavity
T-19A cavity
T-22A cavity
T-23A cavity
T-24A cavity
T-2A cavity
T-31A cavity
T-33A cavity
T-3A cavity
T-5A cavity
T-8A cavity
tuneable
ultra-restrictive
unbalanced poppet
ventable
vented
vent-to-close
vent-to-open
vent-to-operate
vent-to-shift
with check
without reverse flow check
Additional Descriptors
1:1 pilot ratio
1.5:1 pilot ratio
2:1 pilot ratio
2.3:1 pilot ratio
3:1 pilot ratio
4.5:1 pilot ratio
5:1 pilot ratio
6.5:1 pilot ratio
10:1 pilot ratio
10%
15%
20%
30%
50%
2-position
3-position
4-position
6-position
(1 blocked, 2 to 3 open)
(1 to 2 open, 3 blocked)
(3 to 4 open, port 2 blocked)
1/4 NPTF
10.5:1 ratio
120:1 ratio
2 stage
20:1 ratio
3 orifice
4 orifice
6 orifice
6:1 ratio
adjustable stroke limiter
after check
auxillary external port
before check
block port 3 to open
bypass blocked
bypass only
carbide pilot ball
CE marked
control 1-2
control 2-1
CSA approval
Delrin seat
detented
drain to port 3
drain to port 4
external drain port
external pilot port
external port
fixed orifice
flow path switched
Fluid Controls cavity
flush mount
FPS cavity
Gresen cavity
high accuracy
high capacity
high side
hot oil
insert style
internal drain to port 3
load sense
low side
metering notches
normally closed
normally open
open transition
overlap
pilot capacity
pilot source from port 1
pilot source from port 1 or 2
pilot source from port 2
piloted from port 4
piston type
poppet
port 3 blocked
Racine cavity
SAE-4
SAE-6
sealed pilot
short cavity
signal at port 2
signal at port 3
signal external
slow response
spool
standard pilot
stem seal
Waterman 10-2 cavity
Waterman 12-2 cavity
without pilot assist
Manifold Descriptors
Select Body Type
{None}
Bar Manifold
Line mount
Motor mount
Sandwich
Subplate
Select Interface
{None}
0.38 BSP
0.38 NPT
0.50 BSP
0.50 NPT
0.50 SAE C61
0.50 SAE C62
0.75 NPT
0.75 SAE C61
0.75 SAE C62
1.00 SAE C61
1.00 SAE C62
1.25 SAE C61
1.25 SAE C62
1.50 SAE C61
1.50 SAE C62
2.00 SAE C61
2.00 SAE C62
Banjo Bolt
Danfoss OMP
Danfoss OMS
Danfoss OMT
Eaton/Char-Lynn 2000
Eaton/Char-Lynn 4000/6000
Eaton/Char-Lynn H & S
ISO 02
ISO 03
ISO 03 - 30mm
ISO 03 - 40mm
ISO 05
ISO 05 - 50mm
ISO 05 - X&Y
ISO 05 - X&Y (Euro)
ISO 05 - X&Y (US)
ISO 05 - X&Y (US) 50mm
ISO 07
ISO 08
None
SAE 12
SAE 6
SAE 8
Special - 2 bolt
Special - 4 bolt
Staffa 4", 5 piston
Staffa B080/B125/B200
Staffa B150/B200
Staffa B270/B325
Sun
Select Port Size
{None}
1/4" NPTF
3/8" NPTF
1/2" NPTF
3/4" NPTF
1" NPTF
1 1/4" NPTF
SAE 4
SAE 6
SAE 8
SAE 10
SAE 12
SAE 16
SAE 20
1/4" BSPP
3/8" BSPP
1/2" BSPP
3/4" BSPP
1" BSPP
1 1/4" BSPP
1/2" Code 61
1/2" Code 62
3/4" Code 61
3/4" Code 62
1" Code 61
1" Code 62
1 1/4" Code 61
1 1/4" Code 62
1 1/2" Code 61
1 1/2" Code 62
2" Code 61
2" Code 62
M12 x 1.5-6H
M14 x 1.5-6H
M16 X 1.5-6H
M16 x 2.0-6H
M18 x 1.5-6H
M22 x 1.5-6H
M27 x 2.0-6H
Select Feature
{None}
1 Station, Parallel circuit with relief cavity
2 cylinder sequence, direct acting
2 cylinder sequence, with reverse checks
2 Station, Parallel circuit with relief cavity
3 cylinder sequence, with reverse checks
3 signal load sense shuttle body
3 Station, Parallel circuit with relief cavity
4 signal load sense shuttle body
4 Station, Parallel circuit with relief cavity
4 way, combined ports 1 to P, ports 2 to A and B, combined ports 3 to tank
5 signal load sense shuttle body
5 Station, Parallel circuit with relief cavity
6 signal load sense shuttle body
7 signal load sense shuttle body
A and B to T
A or B to T
A or B to T with make up check
A to B
A to B and B to A
A to B or B to A
A to P or B to P
A to T
A to T, external port 3
A to T, check T to B
Adaptor - Adds second T port
Adaptor - Rotates ISO 05 interface by 180 degrees
Adaptor - Switches ports A and B
Adaptor - Switches ports P and T
Adaptor from ISO 03 to ISO 05 (US)
Adaptor from ISO 05 - X & Y (Euro) to ISO 05 - X & Y (US)
Adaptor from ISO 05 - X & Y (Euro) X port to Bosch L port
Adaptor from ISO 05 - X & Y (US) to ISO 05 - X & Y (Euro)
Adaptor from ISO 05 to ISO 05 - X & Y (Euro)
Adaptor from ISO 05 to ISO 05 - X & Y (US)
B to A
B to T
B to T, port 3 external
Bidirectional
Blocking valves on A and B
Common port 1
Common port 2
Cover manifold, 4 way, combined ports 1 to P, ports 2 to A and B and combined ports 3 to T
Cover manifold, 4 way, combined ports 1 to T, ports 2 to A and B and combined ports 3 to P
Cover manifold, 4 way, ISO 03 pilot interface
Cover manifold, 4 way, port 1 to T, port 2 to A, port 3 to P and port 4 to B
Cover manifold, 4 way, ports 1 to A and B, combined ports 2 to P and combined ports 3 to T
Cover manifold, A to B
Cover manifold, all ports blocked
Cover manifold, P to A and B to T
Cover manifold, P to A and B, T blocked
Cover manifold, P to B
Cover manifold, P to B and A to T
Cover manifold, P to T
Cover manifold, P to T, A and B blocked
Cross pilot
Cross pilot on A
Cross pilot on A with shuttle
Cross pilot on B
Cross pilot on B with shuttle
Cross pilot with common port 4s
Cross pilot with independent port 4s
Cross pilot with shuttle
Cross pilot, ninety degree
Cross port
Cross port with gauge ports
Cross port with ISO 03 subplate
Cross port with make up checks
Cross port with shuttle
Cross port with shuttle on port 3s
Cushion lock
Cushion lock with make up checks
Cushion lock with make up checks and shuttle
Cushion lock with shuttle
Direct mount
Direct mount, cross pilot
Direct mount, cross pilot, 2 gasket ports
Direct mount, parallel cavities
Direct mount, through port 2
Do not use
Dual bypass flow control
Dual cavities with common ports 2, 3, and 4
Dual cavity
Dual cross port on A and B, side ports
Dual through port
Flange mount through port
Flow into or out of workport A or B
Flow into workport A
Flow into workport A or out of B
Flow into workport B
Flow into workport B or out of A
Flow into workports A and B
Flow into workports A and B or out of A and B
Four port directional circuit using logic valves, BSP pilot ports
Four port directional circuit using logic valves, NPT pilot ports
Four port directional circuit using logic valves, SAE pilot ports
Gauge adaptor on A and B
High capacity return path
Inline
Inline with reverse flow check
Inline, cross pilot
Inline, cross pilot with shuttle
Into P
Into P and out of T
Into P or out of T
ISO 03 subplate
ISO 05 - X & Y to ISO 03 Adaptor for load sense
ISO 05 subplate
Load sense from A or B to Y port
Meter in A
Meter in A and B
Meter in B
Meter out A
Meter out A and B
Meter out A and B with shuttle
Meter out B
Meter out on A and B with ISO 03 subplate
Ninety degree
Ninety degree with cavity for weatherized coil
Ninety degree with gauge port
Ninety degree with high capacity port 3
Ninety degree with high capacity port 3 and gauge port
Ninety degree with reverse flow check
Ninety degree with reverse flow check - reducing
Ninety degree with reverse flow check - sequence
Ninety degree with shuttle
Ninety degree, 3 ports
Ninety degree, panel mount
Nipple mount
On A
On A with reverse flow check
On A and B
On A and B with cross pilot
On A and B with cross pilot and port 4 external
On A and B with cross pilot and port 4 to T
On A and B, meter out
On A and B, port 3 to T
On A or B
On A or B to T, port 3 external
On A or B with reverse flow check
On A or B, port 3 external
On A or B, port 3 to opposite side
On A with reverse flow check
On A with shuttle
On A, port 3 external
On A, port 3 to B
On A, port 3 to B and port 4 to T
On A, port 3 to T
On B
On B with reverse flow check
On B with shuttle
On B, port 3 external
On B, port 3 to A
On B, port 3 to A and port 4 external
On B, port 3 to A and port 4 to T
On B, port 3 to T
On P
On P, port 3 to T and port 4 external
On P, port 3 external
On P, port 3 to T
On P, port 3 to T - Mirror
On P, port 3 to T, bottom ports
On P, port 3 to T, bottom T port
On P, port 3 to T, manifold T port
On P, port 3 to T, side ports
On P, side ports
On T
On T, port 3 to A
On T, port 3 to B
Out of A
Out of A and B
Out of A, check on P
Out of B
Out of T
P to T
P to T three station
P to T, bottom ports
P to T, check on P, side ports
P to T, manifold T and Y ports
P to T, manifold T port
P to T, port 3 external
P to T, port 3 to Y
P to T, side ports
Parallel cavities
Port 3 connected to port 2
Priority flow control on A with reverse flow check
Priority flow control on B with reverse flow check
Priority flow control on P, bypass to T
Rectifier circuit
Reducer on A with reverse flow check
Reducer on B with reverse flow check
Reducer on A and B with reverse flow check
Reducer on B with reverse flow check
Reducer/reliever on A with reverse flow check and port 4 external
Reducer/reliever on B with reverse flow check and port 4 external
Reducer/reliever on P
Sandwich mount through port
Sandwich/flange mount through port
Sequence into A or out of B with reverse flow check
Sequence into A with reverse flow check
Sequence into B or out of A with reverse flow check
Sequence into B with reverse flow check
Sequence out of A with reverse flow check
Sequence out of B with reverse flow check
Series circuit, 2 to 2
Shuttle between A and B, S port external
Side ports
T to A
T to A and B
T to A or T to B
T to B
T to P
Tap in manifold - A and B
Tap in manifold - P and A or P and B
Tap in manifold - P and A or P and B or T and A or T and B
Tap in manifold - P and T
Tap in manifold - P,T,A and B
Through port
Through port 1 with gauge port
Through port 1 with reverse flow check
Through port 2 with gauge port
Through port 2 with high capacity port 3 and gauge port
Through port 2 with reverse flow check
Through port 2 with reverse flow check and high capacity port 3
Through port 3
Through port with gauge port
With bypass compensator
Select Open Cavity Quantity
0
1
2
3
4
5
6
0
0
0